1.
Braz. dent. j ; 28(1): 9-15, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839109

ABSTRACT

Abstract The high irradiance and the different emission spectra from contemporary light curing units (LCU) may cause ocular damage. This study evaluated the ability of 15 eye protection filters: 2 glasses, 1 paddle design, and 12 dedicated filters to block out harmful light from a monowave (HP-3M ESPE) and a broad-spectrum (Valo, Ultradent) LED LCU. Using the anterior sensor in the MARC-Patient Simulator (BlueLight Analytics) the irradiance that was delivered through different eye protection filters was measured three times. The LCUs delivered a similar irradiance to the top of the filter. The mean values of the light that passed through the filters as percent of the original irradiance were analyzed using two-way ANOVA followed by Tukey test (a= 0.05). The emission spectra from the LCUs and through the filters were also obtained. Two-way ANOVA showed that the interaction between protective filters and LCUs significantly influenced the amount of light transmitted (p< 0.001). Tukey test showed that the amount of light transmitted through the protective filters when using the HP-3M-ESPE was significantly greater compared to when using the Valo, irrespective of the protective filter tested. When using the HP-3M-ESPE, the Glasses filter allowed significantly more light through, followed by XL 3000, ORTUS, Google Professional, Gnatus filters. The Valo filter was the most effective at blocking out the harmful light. Some protective filters were less effective at blocking the lower wavelengths of light (<420 nm). However, even in the worst scenario, the filters were able to block at least 97% of the irradiance.


Resumo A alta irradiância e diferentes espectros de luz emitidos por aparelhos fotopolimerizadores (Fp) podem causar danos oculares. Este estudo avaliou a capacidade de 15 filtros de proteção ocular em bloquear a luz prejudicial de um Fp convencional (HP-3M ESPE) e outro de largo espectro (Valo, Ultradent). Utilizando sensor anterior do equioamento MARC-Patient Simulator (BlueLight Analytics inc.) a irradiância que passou através dos diferentes filtros protetores foi mensuradas três vezes. Os valores médios da irradiância que passaram pelos filtros foram analisados usando Análise de variância fatorial e pelo teste de Tukey (a= 0.05). O espetro emitido dos Fps através dos filtros também foi obtido. A análise de variância mostrou que a interação entre os filtros protetores e Fps influenciou significantemente a quantidade de luz transmitida (p<0,001). O teste de Tukey mostrou que a quantidade que luz transmitida através dos protetores oculares quando usado o HP-3M ESPE foi significantemente maior quando comparado aos valores para o Valo, independentemente do filtro testado. Quando foi utilizado a fonte de luz HP-3M ESPE, o filtro de proteção ocular permitiu significativamente maior passagem de luz, seguido por XL 3000, ORTUS, Google Professional, e pelo filtro Gnatus. O filtro do Valo foi o mais eficiente ao bloquear a luz prejudicial. Alguns filtros foram menos eficazes ao bloquear menores comprimentos de onde (<420 nm). No entanto, mesmo no pior cenário dos resultados deste estudo, os filtros foram capazes de bloquear ao menos 97% da irradiância emitida pelas fontes de luz testadas.


Subject(s)
Humans , Curing Lights, Dental/adverse effects , Eye Protective Devices/standards , Analysis of Variance , Optics and Photonics
2.
J. vasc. bras ; 8(4): 307-312, dez. 2009. ilus
Article in Portuguese | LILACS | ID: lil-543397

ABSTRACT

Contexto: A qualidade e a quantidade de partículas coletadas em filtros de proteção cerebral (FPC) durante angioplastia transluminal percutânea com stent (ATPS) podem esclarecer a importância desses dispositivos no tratamento de estenoses carotídeas. Objetivos: Analisar o conteúdo retido por FPC em pacientes submetidos a ATPS de artéria carótida interna com nova técnica de análise qualiquantitativa. Métodos: O material coletado em 10 FPC durante ATPS da bifurcação da carótida em pacientes com alto risco cirúrgico foi submetido a análise microscópica qualiquantitativa. Fotografias digitais das lâminas com material corado com hematoxilina e eosina foram analisadas com o programa Axio Vision LE Release 4.1, que calculou a área das partículas em micrômetros/metro quadrado (µm²). Resultados: O exame histopatológico evidenciou material em 100 por cento dos filtros consistindo predominantemente de restos hemáticos, cristais de colesterol e cálcio. A área média de fragmentos coletados foi expressiva (1.570.310 µm²), e houve ampla variância desses valores. Conclusões: Os FPC coletam quantidade importante de fragmentos de placas de ateroma, e a grande variância nas quantidades de material coletado pode estar associada com a gravidade da lesão, motivo pelo qual se tornam relevantes estudos que utilizem técnica padronizada para a quantificação desses fragmentos e para a compreensão de seu real significado clínico.


Background: Quality and quantity of the content retained in embolic protection filters (EPFs) used in percutaneous transluminal angioplasty and stenting may possibly indicate the importance of EPFs in the management of carotid stenosis. Objectives: To analyze the content retained by EPFs in patients undergoing percutaneous transluminal angioplasty and stenting of the internal carotid artery using a new technique for qualitative and quantitative analysis. Methods: Material captured in 10 EPFs during percutaneous transluminal angioplasty and stenting in high-surgical-risk patients was examined to determine a qualitative and quantitative microscopic analysis. Digital photographs of the hematoxylin-eosin stained slides were analyzed using the Axio Vision LE Release 4.1 software in order to calculate the particles area in micra/square meter (µm²). Results: Histopathological examination identified particulate debris in 100 percent of the filters including predominantly blood residues, cholesterol crystals, and calcium Quantity of captured fragments was significant (mean of 1,570,310 µm²) with a wide range of these values. Conclusions: Significant quantity of fragments of atheromatous plaques is retained by EPFs and the wide range in the quantity of the retained debris can be associated with the lesion severity; therefore new studies using standardized technique for quantifying these fragments and for better understanding their real clinical meaning are necessary.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Carotid Arteries , Endarterectomy/methods , Endarterectomy , Carotid Stenosis/complications , Carotid Stenosis/diagnosis , Stents